67 Proven Pull-Out Tests – GroundGrabba Strength Results
When Strength Matters, We've Got the Proof
When your assets are on the line, you need anchors that won’t budge. GroundGrabba has been rigorously tested across a wide variety of terrain types—from beach sand to clay, loam to crushed gravel. Below you'll find verified peak pull-out results from over 67 tests, along with linked certification documents and test reports.
Real Data from Real Conditions
These test results are based on field pull-out testing using a hydraulic post puller and crane scale. Each reading reflects the absolute peak load (in kilograms) before failure or extraction.
- Always apply a safety margin.
- Test results vary by soil conditions, moisture, and embedment depth.
- For certification-critical installations, seek engineering sign-off.
See the linked chart and video references below for individual test footage.
GroundGrabba Pull-Out Test Results (Absolute Peak kgs)
The values below in orange have links to the actual video of readings.
Anchor Type | Beach Sand | Softish Grass with sandy substrate | Wet/Damp Dirty Sand | Mixed Clay/Loam | Mixed Clay | Farm-Firm Clay |
---|---|---|---|---|---|---|
GG Junior (GRUJ) | Not Recommended | 36.5 | 32 | 19 | 72.5 | TBA |
Comparison: 300x10mm Spike stake | 3 | 17 | 20 | 7 | 23 | NA |
GroundGrabba Pro 300mm | 21 | 63 | 55.5 | 46 | 99 | 227 |
Comparison: 450x10mm Spike stake | 17.5 | 30 | 42.5 | 19 | 32 | NA |
GroundGrabba Pro I 450mm | 79 | 176 | 158 | 67 | 248 | 443 |
Comparison: 600x10mm Spike stake | 18 | 46 | 49 | 88 | 109 | NA |
GroundGrabba Pro II 600mm | 129 | 290 | 249 | 239 | 239 | 635 |
SR14 | 45 | 101 | 139.5 | 102 | 238 | Too hard (no reading) |
Comparison: 450x15mm Spike stake | 7 | 59 | 47 | 40 | 63 | NA |
GroundGrabba Commercial Pro 450mm | 72 | 368 | 142 | 118 | 316 | NA |
Comparison: 600x15mm Spike stake | 26 | 109 | 69 | 98 | 228 | NA |
GroundGrabba Commercial Pro I 600mm | 142 | 431 | 299 | 299 | 289 | NA |
Comparison: 900x15mm Spike stake | 57 | 70 | 83 | >1000 | 999 | NA |
GroundGrabba Commercial Pro II 900mm | 349 | 509 | 478 | >1000 | 798 | NA |